VENUS DOORS are perfect utilization of full sized frames and battens made from single species of wood for compete strength and its unique pattern. At both sides, lock rails are provided for sufficient grip and thus, making the doors easy to mould, screw and grout, giving them quicker installation. The adhesive are specially tinged with toxicants & antidotes making them strong and giving them great adaptability to outdoor conditions. BWP grade resin is used while manufacturing the doors which provides minimum expansion or contraction during weather changes maintaining their eminent look. We provide safe packing for the same.
S.NO. | Test | ISI Requirements | Observed Values |
---|---|---|---|
1. | Dimensions | Length Width - +5mm Thickness - +1mm |
Within limits |
2. | Squareness | Deviation not more than 1 mm on a length of 500 mm |
Deviation below 1 mm |
3. | General flatness | Twist, Cuppling, Warping not to exceed 6mm |
|
4. | Local Planeness | Depth of deviation at any point to be less than 0.5 mm |
Within limits |
5. | Impact indentation test | Depth of indentation not to exceed 0.2 mm |
Within limits |
6. | Flexure test | The deflection at the maximum load shall not be more than 1/30 of length and 1/15 of width and the residual deflection should not be more than 1/10 |
Satisfactory |
7. | Edge loading test | Deflection of edge with max. To be less than 5 mm. |
Within limits |
8. | Shock resistance test | No visible defect after test | No visible defects |
9. | Buckling test | Initial deflection - < 50 mm residual deflection - < 5 mm |
Within limits |
10. | Slamming test | No visible damage after test | No visible damage |
11. | Misuse test | No deformation after test | No deformation |
12. | Varying humidity test | No visible warping, twisting or de-lamination |
No such defects observed |
13. | End immersion test | No de-lemination at the end | No De-lemination |
14. | Knife test | Excellent | Excellent |
15. | Glue adhesion test | No De-lamination | No De-lamination |
16. | Screw withdrawal test | Load to withdraw the screw shall not be less than 1000 N |
1250 N |